Frequency constrained optimal Power Flow based on Glow-worm Swarm Optimization in Islanded Microgrids
2015
This work presents an application of a swarm optimization method to solve the optimal power flow problem taking into account the constraints of frequency and line ampacity in three-phase islanded Microgrids. Each generation unit is equipped with a Power Electronics Interface. In the considered formulation, the droop control parameters are considered as variables to be adjusted by a higher control level, while the frequency is kept in rated bounds. Another typical constraint for OPF formulation, the max ampacity of each line, is also considered. Two case studies with different dimensions and electrical features have been considered and the obtained results show the efficiency of the proposed…
Optimal Power Flow in three-phase islanded microgrids with inverter interfaced units
2015
In this paper, the solution of the Optimal Power Flow (OPF) problem for three phase islanded microgrids is studied, the OPF being one of the core functions of the tertiary regulation level for an AC islanded microgrid with a hierarchical control architecture. The study also aims at evaluating the contextual adjustment of the droop parameters used for primary voltage and frequency regulation of inverter interfaced units. The work proposes a mathematical method for the OPF solution also considering the droop parameters as variables. The output of the OPF provides an iso-frequential operating point for all the generation units and a set of droop parameters for primary regulation. In this way, …
OPTIMAL POWER FLOW IN ISLANDED MICROGRIDS
In this thesis, studies about OPF in islanded MGs have been carried out. First, an original formulation and solution approach for the OPF problem in islanded distribution systems is proposed. The methodology is well suited for AC microgrids and can be envisioned as a new hierarchical control structure comprising only two levels: primary and tertiary regulation, the latter also providing iso-frequency operating points for all units and optimized droop parameters for primary regulation. The OPF provides a minimum losses operating point for which voltage drops are limited and power sharing is carried out according to the most adequate physical properties of the infrastructure thus giving rise …
Optimal power flow based on glow worm-swarm optimization for three-phase islanded microgrids
2014
This paper presents an application of the Glowworm Swarm Optimization method (GSO) to solve the optimal power flow problem in three-phase islanded microgrids equipped with power electronics dc-ac inverter interfaced distributed generation units. In this system, the power injected by the distributed generation units and the droop control parameters are considered as variables to be adjusted by a superior level control. Two case studies with different optimized parameters have been carried out on a 6-bus test system. The obtained results showed the effectiveness of the proposed approach and overcomes the problem of OPF in islanded microgrids showing loads unbalance.